Spectrum Sensors & Control
Precision Position Sensors & Transducers Advanced Thermal Sensors & Products Company Contact Us Stock Check    
Probes and Assemblies PTC Thermistors NTC Thermistors RTD Sensors
Resistance vs. Temperature
Part Type: 5004A
Temp Scale: °C
Resistance @ 25°C: 50,000Ω
Tolerance @ 25°C: ±2%
Resistance / Temperature Slopes
Temp Range Res Ratio Beta (β)
0 to 50 9.06 3,891
25 to 50 2.78 3,935
25 to 85 9.34 3,976
 
Incremental Temperature Data
Temp
(°C)
Temp
(°F)
Nominal
Resistance
(Ω)
Tolerance
(%)
Temp
Coeff
α % / °C
-40.0-40.01,684,7856.70-6.67
-39.0-38.21,576,5606.61-6.62
-38.0-36.41,475,9736.52-6.57
-37.0-34.61,382,4396.43-6.53
-36.0-32.81,295,4226.34-6.48
-35.0-31.01,214,4306.25-6.44
-34.0-29.21,139,0116.16-6.39
-33.0-27.41,068,7476.07-6.35
-32.0-25.61,003,2575.98-6.30
-31.0-23.8942,1885.89-6.26
-30.0-22.0885,2175.80-6.22
-29.0-20.2832,0445.72-6.18
-28.0-18.4782,3945.64-6.13
-27.0-16.6736,0135.56-6.09
-26.0-14.8692,6685.48-6.05
-25.0-13.0652,1435.40-6.01
-24.0-11.2614,2375.32-5.97
-23.0-9.4578,7665.24-5.93
-22.0-7.6545,5605.16-5.89
-21.0-5.8514,4625.08-5.85
-20.0-4.0485,3265.00-5.81
-19.0-2.2458,0174.92-5.77
-18.0-0.4432,4094.84-5.74
-17.01.4408,3884.76-5.70
-16.03.2385,8474.68-5.66
-15.05.0364,6854.60-5.62
-14.06.8344,8104.52-5.59
-13.08.6326,1384.44-5.55
-12.010.4308,5884.36-5.51
-11.012.2292,0884.28-5.48
-10.014.0276,5674.20-5.44
-9.015.8261,9644.13-5.41
-8.017.6248,2184.06-5.37
-7.019.4235,2753.99-5.34
-6.021.2223,0833.92-5.31
-5.023.0211,5943.85-5.27
-4.024.8200,7643.78-5.24
-3.026.6190,5523.71-5.21
-2.028.4180,9203.64-5.17
-1.030.2171,8303.57-5.14
0.032.0163,2503.50-5.11
1.033.8155,1483.43-5.08
2.035.6147,4953.36-5.04
3.037.4140,2643.29-5.01
4.039.2133,4293.22-4.98
5.041.0126,9663.15-4.95
6.042.8120,8543.08-4.92
7.044.6115,0703.01-4.89
8.046.4109,5972.94-4.86
9.048.2104,4152.87-4.83
10.050.099,5082.80-4.80
11.051.894,8592.74-4.77
12.053.690,4542.68-4.74
13.055.486,2782.62-4.71
14.057.282,3182.56-4.68
15.059.078,5632.50-4.66
16.060.875,0002.44-4.63
17.062.671,6182.38-4.60
18.064.468,4082.32-4.57
19.066.265,3602.26-4.55
20.068.062,4642.20-4.52
21.069.859,7132.16-4.49
22.071.657,0982.12-4.47
23.073.454,6122.08-4.44
24.075.252,2482.04-4.41
25.077.050,0002.00-4.39
26.078.847,8612.08-4.36
27.080.645,8242.16-4.34
28.082.443,8862.24-4.31
29.084.242,0402.32-4.29
30.086.040,2822.40-4.26
31.087.838,6072.46-4.24
32.089.637,0112.52-4.21
33.091.435,4892.58-4.19
34.093.234,0382.64-4.16
35.095.032,6552.70-4.14
36.096.831,3352.76-4.12
37.098.630,0752.82-4.09
38.0100.428,8732.88-4.07
39.0102.227,7252.94-4.05
40.0104.026,6293.00-4.02
41.0105.825,5823.05-4.00
42.0107.624,5823.10-3.98
 
Temp
(°C)
Temp
(°F)
Nominal
Resistance
(Ω)
Tolerance
(%)
Temp
Coeff
α % / °C
43.0109.423,6273.15-3.96
44.0111.222,7133.20-3.93
45.0113.021,8403.25-3.91
46.0114.821,0053.30-3.89
47.0116.620,2063.35-3.87
48.0118.419,4413.40-3.85
49.0120.218,7103.45-3.82
50.0122.018,0103.50-3.80
51.0123.817,3403.55-3.78
52.0125.616,6983.60-3.76
53.0127.416,0833.65-3.74
54.0129.215,4943.70-3.72
55.0131.014,9303.75-3.70
56.0132.814,3893.80-3.68
57.0134.613,8713.85-3.66
58.0136.413,3743.90-3.64
59.0138.212,8973.95-3.62
60.0140.012,4404.00-3.60
61.0141.812,0014.05-3.58
62.0143.611,5804.10-3.56
63.0145.411,1764.15-3.54
64.0147.210,7884.20-3.52
65.0149.010,4154.25-3.51
66.0150.810,0584.30-3.49
67.0152.69,7144.35-3.47
68.0154.49,3844.40-3.45
69.0156.29,0664.45-3.43
70.0158.08,7614.50-3.41
71.0159.88,4684.55-3.40
72.0161.68,1864.60-3.38
73.0163.47,9154.65-3.36
74.0165.27,6544.70-3.34
75.0167.07,4034.75-3.33
76.0168.87,1624.80-3.31
77.0170.66,9294.85-3.29
78.0172.46,7054.90-3.27
79.0174.26,4904.95-3.26
80.0176.06,2835.00-3.24
81.0177.86,0835.04-3.22
82.0179.65,8905.08-3.21
83.0181.45,7055.12-3.19
84.0183.25,5265.16-3.17
85.0185.05,3545.20-3.16
86.0186.85,1885.24-3.14
87.0188.65,0285.28-3.13
88.0190.44,8745.32-3.11
89.0192.24,7255.36-3.09
90.0194.04,5815.40-3.08
91.0195.84,4435.44-3.06
92.0197.64,3095.48-3.05
93.0199.44,1805.52-3.03
94.0201.24,0555.56-3.02
95.0203.03,9355.60-3.00
96.0204.83,8195.64-2.99
97.0206.63,7075.68-2.97
98.0208.43,5995.72-2.96
99.0210.23,4945.76-2.94
100.0212.03,3935.80-2.93
101.0213.83,2955.84-2.92
102.0215.63,2015.88-2.90
103.0217.43,1095.92-2.89
104.0219.23,0215.96-2.87
105.0221.02,9366.00-2.86
106.0222.82,8536.04-2.84
107.0224.62,7736.08-2.83
108.0226.42,6966.12-2.82
109.0228.22,6226.16-2.80
110.0230.02,5496.20-2.79
111.0231.82,4796.24-2.78
112.0233.62,4126.28-2.76
113.0235.42,3466.32-2.75
114.0237.22,2826.36-2.74
115.0239.02,2216.40-2.72
116.0240.82,1616.44-2.71
117.0242.62,1046.48-2.70
118.0244.42,0486.52-2.69
119.0246.21,9946.56-2.67
120.0248.01,9416.60-2.66
121.0249.81,8916.62-2.65
122.0251.61,8416.64-2.64
123.0253.41,7936.66-2.62
124.0255.21,7476.68-2.61
125.0257.01,7026.70-2.60
 
Resistance vs. Temperature Chart